AC Auto Cut Issue. AC problem of auto cut in AC

Auto cut kya hota hai ac mein: In the summer season, AC proves to be a big relief, but when a small malfunction comes in it, the problem also increases a lot. One such common problem is not to work as auto cut. Usually after a time in AC, when the room cools down completely, it is automatically cut. This is called auto cut or thermostat function. But if your AC is going on continuously, without closed, then it means that the auto cut is not working properly. It not only increases power consumption but also puts pressure on the compressor of AC, which can reduce his age. Now the question arises, why does this auto cut stop work? And if this has happened then how to fix it? Let us know in this article in the simple language, so that you can also guess where the problem is and when the technician is needed.

First of all, understand: How does an auto cut work in AC?
The auto cut system is associated with AC thermostat and temperature sensor. Whenever you set a temperature of AC 24 ° C or 26 ° C, AC thermostat continuously works to maintain that temperature. As soon as the room temperature reaches that prescribed level, the AC compressor automatically cut. That is, the coolness persists, but the machine is closed, which saves electricity.

5 common reasons for auto cut in AC

1. Temperature sensor malfunction
If the sensor is not able to catch the room temperature correctly, then thermostat will not get the right signal and the compressor will not be closed.

2. Thermostat malfunction

If thermostat is spoiled, then AC will not know how cold has been done and when to be closed.

3. Gas shortage
If AC has reduced cooling gas (refrigerant), then the coolness will not be properly and the auto cut will not be activated.

4. Fin or filter choke
If AC’s fines or filters are choke with dirt, then the cold air is not able to get out, which slows down the cooling and does not cut the auto.

5. Thermostat location is wrong

If thermostat has installed a place where there is too much heat like direct sunlight or bulb, then it will not be able to read the correct temperature of the room.

How to identify that auto cut is not working?

AC is running continuously without stopping. Feel very cold in the room. The electricity bill suddenly increases. The voice of the compressor of AC kept coming. Despite setting the thermostat, there is no cooling control.

Measures to fix auto cut in AC

1. Check Temperature Settings

First check the temperature of AC, if you are set to 16 ° C or 18 ° C, then the auto cut will be late. Keep it on 24 ° C or 26 ° C.

2. Clean the thermostat
If thermostat has become dirty then clean it with a dry cloth and test it again.

3. Clean Finn and Filter

Remove the AC filter and clean every 10-15 days. Dirty filter affects cooling.

4. Get professional gas check
If you feel that the coolness in AC is decreasing, then it is necessary to check the gas. The compressor will not be closed when there is less gas.

5. Get the sensor and thermostat replacement

If the auto cut is not working even after the above measures, then the sensor or thermostat may have to be replaced.

Some extra tips for better performance of AC
Always run AC in a closed room, so that quickly cools and the auto cut is active quickly. Do AC service every 6 months. Do not reduce the temperature too much, it also increases power consumption and auto cut is late. Never apply thermostat in front of TV, bulb or incense.